500-920 Updated Exam Dumps [2021] Practice Valid Exam Dumps Question [Q10-Q28]

Share

500-920 Updated Exam Dumps [2021] Practice Valid Exam Dumps Question

500-920 Sample with Accurate & Updated Questions


Cisco 500-920 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Troubleshoot storage area networks, including Fibre Channel, FCoE, zoning, NPV, and NPIV
Topic 2
  • Troubleshoot virtualization solutions
Topic 3
  • Troubleshoot FEX
Topic 4
  • Troubleshoot data center unified computing

 

NEW QUESTION 10
What occurs that causes a Split Brain Issue with Fabric Interconnects?

  • A. Manage configuration changes made with UCS Manager
  • B. A quorum tie occurs that must be resolved by the SEEPROM
  • C. The subordinate Fabric Interconnect detects heartbeat failure and declares itself primary
  • D. Both cluster links fail

Answer: C

 

NEW QUESTION 11
What is the result of enabling the Core File Exporter in UCS Manager?

  • A. A core dump must be remotely activated by Cisco TAC.
  • B. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP
  • C. A core dump will immediately be generated and will be exported
  • D. A core dump file will be immediately created and transmitted using HTTP protocol

Answer: C

 

NEW QUESTION 12
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?

  • A. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
  • B. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
  • C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
  • D. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch

Answer: A

 

NEW QUESTION 13
When troubleshooting a LAN connectivity issue, you notice a failed uplink from the Cisco UCS Fabric Interconnects to the upstream LAN switch. What two could be causing the issue? (Choose two )

  • A. A port speed configuration mismatch between the Fabric Interconnects and the upstream LAN switch
  • B. Misconfigured QoS parameters on the failed uplink
  • C. A SFP Type mismatch between the Fabric Interconnects and the upstream LAN switch
  • D. A port channel mismatch between the Fabric Interconnects and the upstream LAN switch
  • E. Misconfigured VLAN on the failed uplink

Answer: B,D

 

NEW QUESTION 14
Which are two Application Gateways primary roles? (Choose two )

  • A. Manage configuration changes made with UCS Manager
  • B. Automate updates to the XML Database
  • C. Manage configuration changes during FSM transitions
  • D. Communicate with virtual machines and report health and state
  • E. Communicate with end points and report their health and state

Answer: B,C

 

NEW QUESTION 15
When it comes to pinning vNIC traffic from a UCS Server to the Fabric Interconnect uplink what configuration can you perform?

  • A. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the same Fabric Interconnect
  • B. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect
  • C. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect
  • D. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect
  • E. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect

Answer: E

 

NEW QUESTION 16
Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?

  • A. The server has a service profile assigned, but has connectivity issues with UCS Manager
  • B. The server has been properly connected, but has not been discovered by UCS Manager
  • C. The server is not properly connected
  • D. The server does not have a service profile assigned, but has been discovered by UCS Manager

Answer: C

 

NEW QUESTION 17
You are experiencing intermittent connectivity issues on one specific Cisco UCS server Some applications work, while other do not transfer data You suspect jumbo frames limitations Which two places do you check the jumbo frame settings? (Choose two )

  • A. Check server's service profile and/or service profile template
  • B. Check upstream switch ports frame size configuration
  • C. Check the fibre channel port configuration for jumbo frame configuration
  • D. Check server's individual vNICs and/or vHBAs properties
  • E. Check server's QoS System Class

Answer: B,E

 

NEW QUESTION 18
Which two ports on a pair of Cisco Fabric Interconnects must be properly cabled for the pair to form a cluster? (Choose two )

  • A. L1 > L2
  • B. L2 > L1
  • C. L1 > L1
  • D. L2 > L2

Answer: C,D

 

NEW QUESTION 19
A new UCS dual fabric cluster is being configured with a single chassis. The administrator notices that the cluster is not in High Availability (HA) mode. What is the possible cause?

  • A. The UCS-FI-HA license has not been activated in UCS Manager
  • B. The HA plugin has not been installed in UCS Manager
  • C. The links to the chassis are not enabled
  • D. No uplinks are active into the data center.

Answer: B

 

NEW QUESTION 20
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?

  • A. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects
  • B. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
  • C. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
  • D. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
  • E. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects

Answer: B

 

NEW QUESTION 21
In Cisco UCS, there are several interfaces involved on the packet path from the vNIC through the adapter, IOM to finally reach Pi Which is the order of those interfaces, starting from the vNIC?

  • A. VIF, UIF, HIF, SIR NIF
  • B. HIF. NIF, UIF, VIF SIF
  • C. VIF, UIF, HIF, NIF SIF
  • D. HIF. SIF, VIF, UIF NIF

Answer: A

 

NEW QUESTION 22
Which are two benefits of integrating Cisco UCS C-series servers with Cisco UCS Manager? (Choose two ) Cisco UCS Manager provides the ability to automatically update C-series firmware and device drivers from a single global interface.

  • A. Cisco UCS Manager uses service profiles and resource pools to allow the deployment of multiple servers with a single common template
  • B. Cisco UCS Manager is able to act as a common centralized management platform for both blade and rack servers in a single domain.
  • C. Cisco UCS Manager can automatically power on and off servers to scale elastically according to application performance demands
  • D. Cisco UCS Manager provides the ability to manage C-series in multiple physical domains from a single global interface

Answer: B

 

NEW QUESTION 23
The command show interface veth 705 is telling you that the bound interface is Ethernet 3/1/2 What is the location of the blade that has veth 705 associated to it?

  • A. Chassis 1. Slot 2
  • B. Chassis 3. Slot 2
  • C. Chassis 3, Slot 1
  • D. There is not enough information

Answer: C

 

NEW QUESTION 24
After performing a UCS firmware upgrade, which two UCS components will require updated drivers? (Choose two )

  • A. RAID Controllers
  • B. Cisco Fabric Interconnects
  • C. Cisco UCS Manager
  • D. VIC Cards and Fiber Channel HBAs

Answer: B,D

 

NEW QUESTION 25
Which ethernet port type is used when configuring UCS Fabric Interconnect connections to Cisco UCS C-series servers?

  • A. Direct Connect Port
  • B. Uplink Port
  • C. Server Port
  • D. Service Profile Port

Answer: B

 

NEW QUESTION 26
......

Pass Cisco 500-920 Premium Files Test Engine pdf - Free Dumps Collection: https://www.real4dumps.com/500-920_examcollection.html