Huawei H19-402_V1.0 exam is an important certification for professionals who work in the data center industry. HCSP-Presales-Data Center Network Planning and Design V1.0 certification demonstrates that professionals have the necessary skills and knowledge to design and implement data center networks that are efficient, scalable, and reliable. HCSP-Presales-Data Center Network Planning and Design V1.0 certification also demonstrates that professionals have the ability to work with customers to understand their needs and design solutions that meet those needs.


Huawei H19-402_V1.0 (HCSP-Presales-Data Center Network Planning and Design V1.0) Certification Exam is designed to test the skills and knowledge of professionals who are involved in the planning and design of data center networks. H19-402_V1.0 exam covers a wide range of topics, including network architecture, protocol analysis, virtualization, and security. It is intended for individuals who work in pre-sales roles, such as network architects, consultants, and engineers, who are responsible for designing and proposing data center network solutions to customers.

 

NEW QUESTION # 83
How many meters can the length of the connecting pipe between the indoor and outdoor units of FusionModule800 air conditioner be less than to avoid refrigerant charging?

  • A. 20 meters
  • B. 30 meters
  • C. 50 meters
  • D. 10 meters

Answer: B


NEW QUESTION # 84
NetEco V6R8C10 can assist in the inspection of various equipment through mobile APP, allowing expert experience to form an inspection template library, reducing the skill requirements of inspection personnel, and also supports offline inspection via mobile APP.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 85
What is the length of the power module of 2.4mva FusionPower6000?

  • A. 14m
  • B. 14.80m
  • C. 13m
  • D. 13.08m

Answer: B


NEW QUESTION # 86
When only supporting temperature detection and not supporting hot-swap configuration, the switches in the plug-in frame must be fully equipped.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 87
Which of the following statements about wet film humidification is correct? (Multiple choice)

  • A. Energy saving of 95%+ compared to electrode humidification, better life cycle TCO
  • B. No heating required
  • C. Increased wind resistance
  • D. Compared with electrode humidification, it has lower requirements on water quality and does not require additional water treatment equipment

Answer: A,B,C,D


NEW QUESTION # 88
The number of batteries in traditional UPS cannot be adjusted, and the battery maintenance cost is high. If one battery is damaged, the entire battery group may need to be replaced. The number of batteries in UPS5000-A can be adjusted, so what is the adjustable range?

  • A. 36-40
  • B. 30-40
  • C. 32-40
  • D. 34-40

Answer: B


NEW QUESTION # 89
At which of the following voltages is the lead-acid battery already in a dangerous state?

  • A. 2.45
  • B. 2.25
  • C. 1.67
  • D. 2.35

Answer: A


NEW QUESTION # 90
Fusionmodule2000 single-row cabinet scenario does not support configuration of sliding doors/electric doors

  • A. True
  • B. False

Answer: A


NEW QUESTION # 91
A system is configured with a 15-minute battery backup time. The discharge termination voltage of a single battery cell should be selected as ().

  • A. 1.75V
  • B. 1.60V
  • C. 1.67V
  • D. 1.80V

Answer: C


NEW QUESTION # 92
iBattery intelligent battery management can monitor the parameters of a single battery in detail.
What are these parameters? (Multiple choice)

  • A. Voltage
  • B. Temperature
  • C. Electric current
  • D. Internal resistance

Answer: A,B,C,D


NEW QUESTION # 93
In a project, it is required to deploy three-layer temperature cloud maps in high-density areas. How many temperature probes need to be deployed in each cabinet?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B


NEW QUESTION # 94
In a certain project, the customer hopes to show the data center operation and maintenance status to external visitors. In this case, the () function of the NetEco management system can be used to achieve this?

  • A. Large screen display
  • B. Alarm Management
  • C. Report Management
  • D. Energy Efficiency Management

Answer: A


NEW QUESTION # 95
The standard stipulates that the voltage drop of AC cables should be controlled within 3%. When designing a UPS system, it is recommended that the voltage drop of AC cables be controlled within ().

  • A. 0.01
  • B. 0.03
  • C. 0.05
  • D. 0.02

Answer: A


NEW QUESTION # 96
Huawei's NetEco network management system supports the southbound SNMP protocol.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 97
The bypass module of UPS5000-E-200K (50kVA power module) is the same as that of UPS5000-E-
300K

  • A. True
  • B. False

Answer: A


NEW QUESTION # 98
The mechanical supplementary cooling ratio is ()

Answer:

Explanation:
10%-50%


NEW QUESTION # 99
Battery packs of different brands and the same capacity can be used in parallel.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 100
Three-proof paint coating can significantly reduce the failure rate of UPS in harsh environments such as salt spray, dust, high temperature and humidity, and ensure its service life in harsh environments.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 101
What is the system efficiency of UPS5000-E?

  • A. 97.50%
  • B. 96%
  • C. 96.50%
  • D. 97.10%

Answer: B


NEW QUESTION # 102
The NetEco6000 management system can realize APP+intelligent inspection, greatly reducing operation and maintenance hours.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 103
Fusionmodule2000 cabinet widths are 600 and 800 mm

  • A. True
  • B. False

Answer: A


NEW QUESTION # 104
If UPS5000-A-400/500K is equipped with a set of 40 12V batteries, how many battery inspection meters are needed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 105
Which of the following is the correct statement about circuit breakers? (Multiple choice)

  • A. Circuit breakers play a dual role of isolation and protection in the system
  • B. When selecting a circuit breaker, do not consider the redundancy
  • C. Isolating switches and circuit breakers play the same role in the system
  • D. Leakage protection circuit breaker is not recommended to be used at the front end of the UPS system

Answer: A,B,C,D


NEW QUESTION # 106
In UPS5000 configuration, the power supply reliability level cannot be selected.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 107
What is the maximum IT load supported by the FusionModule2000 integrated UPS, and how many power modules does it support at most?

  • A. 150KW, 7 25KVA power modules
  • B. 150KW, 6 25KVA power modules
  • C. 125KW, 6 25KVA power modules
  • D. 125KW, 5 25KVA power modules

Answer: C