Enhance your career with NS0-593 PDF Dumps - True Network Appliance Exam Questions
New (2022) Download free NS0-593 PDF for Network Appliance Practice Tests
NEW QUESTION 10
Your customer complains that u host will constantly report losing a connection to the iSCSl target and then
report that the session was reestablished.
As shown in the exhibit, what is a cause of this flapping?
- A. A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 have the
same IQN. - B. A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 are
accessing the same LUN. - C. A host with an IP address of 172.20.10.80 and a secondIP address of 10.10.20.60 is accessing different LUNs.
- D. A host with an IP address of 172.20.10.80 and a secondhost with an IP address of 10.10.20.60 are in
different initiator groups.
Answer: B
NEW QUESTION 11
A customer calls you to troubleshoot a network issue. The customer wants to create a packet trace for allclients
on the 192.168.9.0/24 subnet.
Referring to the exhibit, on which interface do you have to run the packet trace?
- A. e2a-1092
- B. a0a-456
- C. a0a-322
- D. e2a-100
Answer: A
NEW QUESTION 12
Your customer mentions that they have accidentally destroyed both rootaggregates in their two-node cluster.
In this scenario, what are two actions that must be performed? (Choose two.)
- A. Re-create the cluster from the local backup.
- B. Install ONTAP from a USB device.
- C. Re-create the cluster from the remote backup.
- D. Rejoin the second node to the re-created cluster.
Answer: B,D
NEW QUESTION 13
You are trying to deploy a Connector in the AWScloud from NetApp Cloud Manager. The deployment fails
and shows the message 'Insufficient permissions to deploy Cloud Connector". You have verified the AWS
access key and the AWS secret key.
In this scenario, what Is the reason that the deployment failed?
- A. No AWS Marketplace subscription is associated with Cloud Manager.
- B. The user lacks the permission to deploy within Cloud Manager.
- C. The Connector can be deployed only inAWS GovCloud (US).
- D. The required Identity and Access Management (IAM) policies were not Installed.
Answer: B
NEW QUESTION 14
Your customer noticed in NetApp Active IQ that their NetApp Cloud Volumes ONTAP forAzure HA solution
is no longer sending AutoSupport messages over HTTPS. A support ticket has been opened to find out why.
No changes have been made to the Cloud Volumes ONTAP for Azure HA environment.
In this scenario, which two autosupport command parameters should be used to validate that AutoSupport Is
working properly? {Choose two.)
- A. -to
- B. -mail-hosts
- C. -transport
- D. -proxy-url
Answer: B,D
NEW QUESTION 15
You have a 4-node NetApp ONTAP 9.8 cluster with an AFF A400 HA pair and a FAS8300 HA pair with 16
TB NL-SAS drives. You are asked to automatically tier 150 TB of Snapshot copy data from the AFF A400
aggregates to the FAS8300.
In this scenario, which ONTAP license must be added to the cluster to accomplish this task?
- A. VE license
- B. TPM license
- C. S3 license
- D. FabricPool license
Answer: B
NEW QUESTION 16
The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02.
Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess
fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?
- A. While in maintenance mode, the fcadmin device_map command was executed.
- B. While in maintenance mode, the mailbox destroy local command was executed.
- C. While in maintenance mode, the sldiag device show command was executed.
- D. While in maintenance mode, the HA_config show command was executed.
Answer: A
NEW QUESTION 17
You receive the panic message shown in the exhibit.
In this scenario, which component should you troubleshoot first?
- A. the PCI card in slot 3
- B. the memory module in slot 1
- C. the CPU
- D. the MetroCluster FC-Vl card in slot 6
Answer: C
NEW QUESTION 18
You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need
to know the storagelimits.
In this scenario, which source should be reviewed?
- A. Hardware Universe
- B. Cloud Central
- C. NetApp Cloud Volumes ONTAP Release Notes
- D. Interoperability Matrix Tool (IMT)
Answer: C
NEW QUESTION 19
A user reports that a colleague saved a file called Test.txt from a UNIX system to a multiprotocol volume.
When opening the file later from a Windows system, it was not the file that they wanted. The file that they
wanted was named TEST~1.TXT.
Which statement explains this behavior?
- A. Windows Volume Shadow Copy Service stored an older version of the file.
- B. UNIX name mapping updated the filename.
- C. Case Insensitivity of SMB clients caused the file to be displayed with a different name.
- D. A Snapshot copy preserved two versions of the file.
Answer: D
NEW QUESTION 20
You have recently discovered that NetApp ONTAP Cloud Manager is not sending AutoSupport messages to
NetApp.
In this scenario, what would solve this Issue?
- A. Verify that your NetApp Support site credentials are correctly added to Cloud Manager.
- B. Verify that the inbound and outbound rules allow AutoSupport on port 80.
- C. Verify that your data LIFs allow traffic to mysupport .netapp.com on port 443.
- D. Verify that your AWScredentials are correctly added to Cloud Manager.
Answer: C
NEW QUESTION 21
You want to assign storage access to an NVMe protocol host.
Which three objects must beconfigured to accomplish this task? (Choose three.)
- A. the NVMe broadcast domain
- B. the NVMe namespace
- C. an NVMe LUN
- D. the NVMe subsystem
- E. an NVMe LIF
Answer: A,D,E
NEW QUESTION 22
When an administrator tries to create a share for an existing volume named voll, the process fails with an error.
Referring to the exhibit, what Is the reason for the error?
- A. The volume must have a type of DP.
- B. The volume has not beenmounted.
- C. The CIFS service is not in workgroup mode.
- D. The CIFS service is not authenticating properly with the domain controller.
Answer: B
NEW QUESTION 23
A customer's storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature
on their MetroCluster IP environment.
What Information would you tell your customer in this scenario?
- A. This is a configuration failure, you can activate that feature for the customer.
- B. The AUSO feature is not available in Metrocluster IP installations by design.
- C. The AUSO feature cannot be activated due to a non-mirrored aggregate.
- D. A faulty link automatically deactivated the AUSO feature.
Answer: C
NEW QUESTION 24
You are attempting to connect a NetApp ONTAP cluster to a very complex network that requires LIFs to fail
over across subnets.
How would youaccomplish this task?
- A. Configure VIP LIFs using OSPF.
- B. Configure VIP LIFs using BGP.
- C. Configure a I IF failover policy for each subnet inside a single broadcast domain.
- D. Configure an equal number of UFs on each subnet.
Answer: B
NEW QUESTION 25
Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP
9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are
placed into the FlexGroup volume.
In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)
- A. -v4-fsid-change
- B. -v3-64bit-identifiers
- C. -v4-64bit-idantifiers
- D. -v3-fsid-change
Answer: B,D
NEW QUESTION 26
After a normal power down of both nodes forbuilding maintenance, Node01 of a 2-node cluster cannot be
powered back up; however, all disk shelves are powered.
Which action should be performed to bring the cluster online and allow Node02 to serve data?
- A. Reboot the node With the system node reboot -node Node02 -bypass-optimization true command.
- B. Recreate the cluster with the system configuration recovery cluster recreate -from node command.
- C. Reinitialize the cluster with option 4a from the boot menu.
- D. Perform a takeover with the storage failover takeover -ofnode Node01 -option forcecommand.
Answer: B
NEW QUESTION 27
You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size
of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and
you receive anout of apace error message on your host.
What would cause this error?
- A. The inode limit is exceeded in the ONTAP software.
- B. The maximum number of volume constituents has been reached in the ONTAP software.
- C. The maxdirsize Is exceeded in the ONTAP software.
- D. All constituent volumes are full.
Answer: A
NEW QUESTION 28
......
Network Appliance NS0-593 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
100% Free NS0-593 Files For passing the exam Quickly: https://www.real4dumps.com/NS0-593_examcollection.html
NS0-593 Dumps Questions Study Exam Guide : https://drive.google.com/open?id=1v_hJ7OGZHbqcsQtbYpzkzWSpB60oarYa